fbpx

D11 Retrofit Solutions in light of Early Life Expectancy 

Relative to historical industry experiences, D11 steam turbines have come of age at an early stage in their lifecycle and are strong candidates for retrofit solutions.   The most common reasons reported to MD&A for prompting retrofit consideration include (1) reliability issues, (2) technology obsolescence, and (3) changes within plant operating missions and steam cycles (e.g. modifications to the boiler or combustion turbines from initial design).  Commonly, these drivers led to retrofits after 20 to 30+ years of operation.  However; the experience of progressive major reliability and operational issues coupled with outdated technology warrants the evaluation of a retrofit solution compared to continuously increasing maintenance costs.

In MD&A’s experience, significant mechanical failures, particularly in the High Pressure (HP) and Intermediate Pressure (IP) sections, such as rotor cracking, shell, and N2 packing head cracking, continue to worsen in both severity of the defects as well as the frequency of occurrence.  In addition, other reliability issues such as poor vibration characteristics bowed rotors, and diaphragm dishing further contribute to increasing losses in a unit’s thermal performance.

The underlying reasons for the early maturation of the D11 fleet are varied.  The application of low-alloy, single-shell configurations operating at 1050 F is a major factor in the reliability issues of the D11.  However; the evolution of operational demands for combined cycle power plants also plays a major role in minimizing life expectancy.  Early industry expectations were that combined cycle plants would be primarily base-loaded.  However; as the industry matured, combined-cycle plants were eventually required to be capable of sustained, frequent load cycling, and start/stop operational profiles.  By itself, frequent cycling can be a sufficient cause for early-onset mechanical failures. The coupling of operational cycling with single-shell, low-alloy components of the D11 has a multiplying effect.  Based on reported feedback, the severity and range of mechanical issues for the D11 fleet continue to progress with time.

In circumstances where it is determined that the best approach is to repair and maintain existing turbine hardware, Mechanical Dynamics & Analysis (MD&A) offers a full complement of turn-key field services, repairs, and parts.  MD&A has a 16-year history of supporting the D11 fleet including such services as weld repair of cracked packing heads, straightening of bowed rotors, diaphragm repairs, installation of advanced sealing packages, and steam valve internal component manufacturing and replacements.  MD&A is also recognized as an industry vanguard in the area of fossil steam turbine shell weld repairs for over 20+ years.

Additionally, for units that experience progressive reliability issues, spiraling maintenance costs lost thermal performance, and electrical generation, a 15-20 year life-cycle Cost of Electricity (COE) evaluation suggests a retrofit which, in comparison to continuous maintenance expense, significantly outperforms the later on a net present value basis (NPV).  The magnitude of NPV spread is primarily dictated by unit/customer-specific data.  As an example, shell cracking at the main fit ultimately necessitates shell replacement for long-term resolution as a weld repair is considered only a temporary solution to return the unit to service.  Shell cracking is also common at other locations such as the HP and IP inlet areas.  The Discovery of shell cracking during maintenance inspections or as a root cause for forced outages results in high repair costs and disruption to the owner’s operations.  Additionally, the discovery of rotor cracking, depending upon the severity and location, may necessitate rotor replacement prior to the unit returning to service.  As rotors are a long lead component, this scenario suggests it prudent to plan for turbine replacement prior to reaching end-of-life on critical components such as rotors.

MD&A, in conjunction with its parent company Mitsubishi Power, has developed a “Drop-In” retrofit solution for the D11 HP/IP which addresses fleet reliability concerns, providing excellent availability, and enhanced thermal performance.  The MD&A/Mitsubishi Power design was created by leveraging proven steam turbine technologies from Mitsubishi Power.  Given Mitsubishi Power’s extensive combined-cycle fleet experience, our design team was able to develop a retrofit solution that maintains plant interfaces.  Each retrofit offered by MD&A/Mitsubishi Power is custom designed and optimized for its unique application and includes replacement of the existing flexible, low alloy shell with a robust, double-shell construction utilizing high chrome material within high-temperature locations.  The new shell facilitates the implementation of other improvements such as a larger diameter rotor with excellent vibration characteristics and incorporation of a high-efficiency steam path.  Similar to the double-shell, these components also utilize a robust mechanical design including high chrome material for superior creep characteristics.

D11 Retrofit

Inherent with the retrofit, an opportunity exists for re-optimization of the steam bottoming cycle including an increase in duct firing.  In situations where plant operating missions are modified, combustion turbines are upgraded, or duct firing profiles are altered, resetting the unit design point can provide the end-user with significant value.  Design re-optimization can yield major cost-saving benefits beyond the resolution of reliability and thermal performance deficiencies.

Through its services experience and detailed engineering study of the D11 fleet and configuration, MD&A/Mitsubishi Power has developed an HP/IP “Drop-In” retrofit solution based upon proven steam turbine technology with a projected payback within 2-3 years.  For more information, contact MD&A at (518) 399-3616 or use our contact form.

 

Also, read how MD&A has expertise in innovative D11 repair solutions while delivering consistent quality and value along with superior communications.

Tags: , ,

Email This article | Print This Article

Contact

Submit the below form or visit our main 24/7 Contact & Locations page.

"*" indicates required fields

Name*
This field is for validation purposes and should be left unchanged.