Incremental Circuit Upgrades
MD&A Control Systems Division has more than 500 circuits installed
in 57 power stations throughout the United States.
Download Control
Systems Catalog (pdf - 431 KB)
An
abbreviated list of incremental circuit upgrades available from
MD&A includes:
- Back-Up Control System: Bypasses primary control circuitry
to allow on-line maintenance.
- Back-Up Overspeed Trip F/V: Replaces Megacycler based
OEM circuit with more stable F/V speed sensing.
- Circuit Extender Card: Two piece extender with test points
allows for enhanced analog and logic troubleshooting.
- Control Panel Replacement: Completely isolated from cabinet
power for increased reliability. All digital metering and set-point
controls.
- Digital Admission Transfer Circuit: Replaces electro-mechanical
FA/PA motor drive, motor pulsing circuitry and associated voltage
comparators.
- Digital Load Reference Circuit: Digital Load Reference
Circuit Replaces OEM circuit with more stable amplification and
adds decrease loading ramps.
- Digital Load Set Circuit: Replaces the electro/mechanical
Load Set Motor Drive assembly.
- Digital Position Control Circuit: Replaces the Diode
Function Generator valve position circuit, with a programmable
digital circuit.
- Digital Set Point Circuit: Replaces any manual or motor
driven set point pot.
- FA/PA Voltage Comparator: Eliminates the FA/PA transfer
limit switches located in the steam valve junction boxes.
- Frequency to Voltage Converter: Direct replacement for
OEM F/V's or replaces older Megacycler circuits.
- High Voltage Logic Circuit: Replaces High Voltage Mercury
wetted relay boards with solid state switches.
- IC Operational Amplifier: Replaces discreet component
amplifiers or OEM IC op amps and has on board spare.
- Integrated Valve Driver Circuit: Replaces SADI boards
and eliminates 3KC oscillators.
- Isolated Buffer Circuit: Provides isolation for monitoring
of analog signals by other plant system with a wide range of outputs.
- Linear Variable Transformer Circuit: For pilot valve
and operator cylinder position sensing.
- Low Voltage Logic Circuit: Replaces Low Voltage Mercury
wetted relay boards with solid state switches.
- Meter Relay Replacement: Monitors trip test functions
with solid state voltage comparators eliminating troublesome meter
relays.
- Stage Pressure Bias Circuit: Gives a bumpless transfer
to stage pressure feedback operation during valve testing.
- Throttle Pressure Limiter Circuit: Enhances limitter
operation for sliding pressure operation and locks out limit action
on transmitter failure.
- Time Delay Relay Circuit: Replaces antiquated timers
with solid state equivalent.
- Valve Feedback Circuit: Provides wide range adjustable
feedback signal from non servo controlled valves.
- Voltage Comparator: Direct replacement for OEM circuit.
- Voltage Sensor Circuit: Replaces obsolete OEM power supply
monitor circuits.
For more information on MD&A Control Systems' products and
services, please call (970) 224-2223 Ext. 140 or email: amcneill@mdaturbines.com
|